Description
The Schneider Electric KAL361501380 is a three pole molded case circuit breaker designed for dependable protection in industrial and commercial power distribution systems. It provides thermal magnetic protection with long-time and instantaneous trip functions to support controlled operation in three-phase applications.
Technical Specifications
| Condition |
New/Never Used Surplus |
| Brand |
Schneider Electric / Square D |
| Category |
Circuit Protection |
| Part Number |
KAL361501380 |
| Subcategory |
Molded Case Circuit Breakers |
| Series |
KAL Series |
| Frame Type |
K Frame |
| Type |
KAL |
| Amperage Rating |
150 A |
| Voltage Rating |
600 VAC |
| Number of Poles |
3 |
| Phase |
3 Phase |
| Interrupting Rating |
25 kA @ 480 V |
| Protection Type |
Thermal Magnetic |
| Trip Functions |
Long-Time and Instantaneous (LI) |
| Connection Type |
Feed-Thru |
| Mounting Type |
Unit Mount |
| Wire Size |
#4 AWG to 350 kcmil (Al/Cu) |
| Certifications |
UL Listed, CSA Certified, IEC Rated |
| Dimensions (W x D x H) |
4.50 x 4.75 x 8.00 in |
| Weight |
9 lbs |
Information About KAL361501380
The KAL361501380 is part of the Schneider Electric Square D KAL Series, developed for molded case circuit breaker applications requiring consistent performance and standard interrupting capacity. This breaker supports three-phase electrical systems with a continuous current rating of 150 amps and an operating voltage of up to 600 VAC. It incorporates a thermal magnetic trip unit that provides coordinated protection against overloads and short-circuit conditions through long-time and instantaneous response. The K-frame construction and feed-thru connection design allow reliable integration into industrial enclosures and power distribution equipment.
Key Features
- Thermal Magnetic Trip Unit: Combines thermal overload protection with instantaneous magnetic tripping to safeguard circuits against overcurrent and short-circuit faults.
- Three Pole Configuration: Provides simultaneous protection across all phases for balanced three-phase power distribution.
- Standard Interrupting Capacity: Rated at 25 kA at 480 V to safely interrupt fault currents in commercial and industrial systems.
- K-Frame Molded Case Design: Engineered for mechanical strength, thermal stability, and long service life in demanding environments.
- Feed-Thru Connection Layout: Supports straight-through power flow and simplified wiring within distribution panels.
- Wide Conductor Compatibility: Accepts a broad range of aluminum and copper conductor sizes for flexible installation.
- Certified Compliance: UL Listed, CSA Certified, and IEC Rated to meet recognized electrical safety and performance standards.
The KAL361501380 delivers the reliability and precision required for protecting three-phase power distribution circuits in industrial and commercial applications.