ASA5516-FPWR-K9 Specification
|
| Product Number |
ASA5516-FPWR-K9 |
| Throughput:Application Control (AVC) |
850 Mbps |
| Throughput:Application Control (AVC) and IPS |
450 Mbps |
| Maximum concurrent sessions |
250,000 |
| Maximum New Connections per second |
20,000 |
| Supported applications |
More than 3,000 |
| URL categories |
80+ |
| Number of URLs categorized |
More than 280 million |
|
Centralized configuration, logging,
monitoring, and reporting
|
Multi-device Cisco Security Manager (CSM)
and Cisco Firepower Management Center
|
| On-Device Management |
ASDM (version 7.3 or higher required) |
| Feature |
Cisco ASA 5516-X w/ FirePOWER Services |
| Stateful inspection throughput (maximum) |
1.8 Gbps |
| Stateful inspection throughput (multiprotocol) |
900 Mbps |
|
Triple Data Encryption Standard/ Advanced Encryption Standard
(3DES/AES) VPN throughput
|
250 Mbps |
| Users/nodes |
Unlimited |
| IPsec site-to-site VPN peers |
300 |
|
Cisco AnyConnect Plus/Apex VPN
maximum simultaneous connections
|
300 |
| Virtual interfaces (VLANs) |
100 |
| Security contexts(included; maximum) |
2; 5 |
| High availability |
Active/Active and Active/Standby |
|
Integrated Wireless Access Point
(See Cisco AP 702 datasheet for
WiFi technical details)
|
N/A |
| Expansion slot |
N/A |
| User-accessible Flash slot |
No |
| USB 2.0 ports |
USB port type ‘A’, High Speed 2.0 |
| Integrated I/O |
8 x 1 Gigabit Ethernet (GE) |
| Expansion I/O |
N/A |
| Dedicated management port |
Yes (To be shared with FirePOWER Services), 10/100/1000 |
| Serial ports |
1 RJ-45 and Mini USB console |
| Solid-state drive |
100 GB mSata |
| Memory |
8 GB |
| System flash |
8 GB |
| System bus |
Multibus architecture |
| Temperature |
32 to 104°F (0 to 40 °C) |
| Relative humidity |
10 to 90 percent noncondensing |
| Altitude |
Designed and tested for 0 to 10,000 ft (3048 m) |
Acoustic noise
|
41.6 dBA type |
| Temperature |
-13 to 158ºF (-25 to 70ºC) |
| Relative humidity |
10 to 90 percent noncondensing |
| Altitude |
Designed and tested for 0 to 15,000 ft (4572 m) |
| AC range line voltage |
External, 90 to 240 volts alternating current (VAC) |
| AC normal line voltage |
90 to 240 VAC |
| AC current |
0.25AC amps |
| AC frequency |
50/60 Hz |
| Dual-power supplies |
None |
| DC domestic line voltage |
N/A |
| DC international line voltage |
N/A |
| DC current |
N/A |
| Steady state |
12V @ 3.0A |
Maximum peak
|
12V @ 5.0A |
Maximum heat dissipation
|
205 Btu/hr |
| Form factor |
1 rack unit (RU), 19-in. rack-mountable |
| Dimensions(H x W x D) |
1.72 x 17.2 x 11.288 in. |
| Weight (with AC power supply) |
8 lb (3 kg) |