ASA5506-K9 Specifications
|
| Type |
Cisco ASA 5506-X w/ FirePOWER Services |
Throughput: Application Control (AVC)
|
250 Mbps |
Throughput: Application Control (AVC) and IPS
|
125 Mbps |
| Maximum concurrent sessions |
20,000; 50000 |
| Maximum New Connections per second |
5000 |
|
Supported applications
|
More than 3,000 |
|
URL categories
|
80+ |
|
Number of URLs categorized
|
More than 280 million |
|
Centralized configuration, logging,
monitoring, and reporting
|
Multi-device Cisco Security Manager (CSM) and Cisco Firepower Management Center |
| On-Device Management |
ASDM (version 7.3 or higher required) |
| Feature |
Cisco ASA 5506-X w/ FirePOWER Services |
| Stateful inspection throughput (maximum1) |
750 Mbps |
| Stateful inspection throughput (multiprotocol2) |
300 Mbps |
|
Triple Data Encryption Standard/ Advanced Encryption Standard (3DES/AES)
VPN throughput3
|
100 Mbps |
| Users/nodes |
Unlimited |
| IPsec site-to-site VPN peers |
10; 50 |
|
Cisco AnyConnect Plus/Apex VPN
maximum simultaneous connections5
|
50 |
| Virtual interfaces (VLANs) |
5; 30 |
| Security contexts5(included; maximum) |
N/A |
| High availability |
Requires Security Plus License; Active/ Standby |
|
Integrated Wireless Access Point (See Cisco AP 702 datasheet for
WiFi technical details)
|
N/A |
| Expansion slot |
N/A |
| User-accessible Flash slot |
No |
| USB 2.0 ports |
USB port type ‘A’, High Speed 2.0 |
| Integrated I/O |
8 x 1 Gigabit Ethernet (GE) |
| Expansion I/O |
N/A |
| Dedicated management port |
Yes (To be shared with FirePOWER Services), 10/100/1000 |
| Serial ports |
1 RJ-45 and Mini USB console |
| Solid-state drive |
50 GB mSata |
| Memory |
4 GB |
| System flash |
8 GB |
| System bus |
Multibus architecture |
| Temperature |
32 to 104°F (0 to 40 °C) |
| Relative humidity |
90 percent noncondensing |
| Altitude |
Designed and tested for 0 to 10,000 ft (3048 m) |
| Acoustic |
Fanless |
| noise |
0 dBA |
| Temperature |
-13 to 158ºF (-25 to 70ºC) |
| Relative humidity |
10 to 90 percent noncondensing |
| Altitude |
Designed and tested for 0 to 15,000 ft (4572 m) |
| AC range line voltage |
External, 90 to 240 volts alternating current (VAC) |
| AC normal line voltage |
90 to 240 VAC |
| AC current |
N/A |
| AC frequency |
50/60 Hz |
| Dual-power supplies |
None |
| DC domestic line voltage |
N/A |
| DC international line voltage |
N/A |
| DC current |
N/A |
| Steady state |
12V @2.5A |
| Maximum peak |
12V @ 5A |
| Maximum heat dissipation |
103 British thermal units (Btu)/hr |
| Form factor |
Desktop, rack mountable |
| Dimensions |
1.72 x 7.871 x 9.23 in. |
| (H x W x D) |
(4.369 x 19.992 x 23.444 cm) |
| Weight (with AC power supply) |
4 lb (1.82 kg) |